During dental care, surfaces, instruments and equipment can come into contact with saliva, blood, aerosols and other potentially contaminating materials. Therefore, biosecurity needs to work as a continuous process, and not as a quick cleanup carried out when the previous patient leaves.
Standard precautions are applicable to all patientsregardless of whether an infection is suspected or confirmed (CDC, 2024).
As soon as the service ends, the materials used need to go to different destinations.
Single-use items must be discarded after care and cannot be reused on another patient. Reusable instruments need to enter the appropriate processing flow, considering their risk classification and the manufacturer's instructions (CDC, 2024).
In Brazil, RDC nº 15/2012 establishes that the processing of health products must follow a directed flow from the dirty area to the clean area, avoiding crossings that could favor recontamination (ANVISA, 2012).
This means that the contaminated instruments should not simply “return to the plant”.
There is a processing flow.
Not everything that needs to be sanitized is an instrument.
Surfaces frequently touched during care — such as reflector handles, chair controls, trays, switches and certain equipment — can be contaminated by contact, splashes or aerosols (CDC, 2024).
Therefore, between patients:
disposable barriers must be removed and replacedwhen used;
non-barrier clinical surfaces must be cleaned and disinfected;
and the product used must be compatible with the surface and used according to the manufacturer's instructions, including concentration and contact time (CDC, 2024).
An important detail:
Cleaning and disinfecting are not the same thing.
Cleaning removes dirt and organic matter; disinfection is a subsequent step aimed at inactivating microorganisms. Proper cleaning is necessary before disinfection when there is surface contamination (CDC, 2024).
range It may seem obvious, but it is one of the most important measurements.
The CDC considers hand hygiene to be the most important measure to prevent the spread of infections among patients and staff. It must be performed before and after each service and also at specific times during the procedure, such as after contact with potentially contaminated materials (CDC, 2024).
And there is a fundamental difference:
Gloves do not replace hand hygiene.
Hands must be sanitized before putting on gloves and again after removing them.
Furthermore, touching clean objects with contaminated gloves can transform apparently “clean” equipment into a transfer point for microorganisms.
After the patient, the contaminated instrument must go through a sequence.
Safe transport → cleaning → inspection → preparation/packaging → sterilization → monitoring → storage.
Cleaning comes before sterilization because blood, saliva and other organic residues can protect microorganisms and compromise the effectiveness of the following steps (CDC, 2024).
And sterilization also needs to be monitored. The CDC recommends the combined use of indicatorsmechanical, chemical and biological to verify whether the sterilizer has reached the necessary conditions for the process (CDC, 2024).
Therefore, “the instruments went to the autoclave” is not synonymous with: “the instruments are ready for the next patient.”
Perhaps this is the most important idea.
The interval between patients should not be measured just by the clock:
“I have 10 minutes to prepare the room.”
The question should be:
“Have all necessary steps been completed to make this environment and materials safe for the next patient?”
This involves:
correct disposal of single-use materials;
safe removal of contaminated items;
adequate processing of reusable instruments;
replacement of barriers;
cleaning and disinfection of clinical surfaces;
hand hygiene;
reorganization of the environment;
availability of clean and sterilized materials for the next service.
The CDC itself recommends that services have written infection prevention and control policies and procedures, with defined responsibilities and periodic review (CDC, 2024).
It is a system.
The patient who has just left does not “take” full responsibility for what happened in the room.
The environment, instruments and equipment need to go through a process that allows to interrupt the transmission chain before the next service begins.
And this requires more than alcohol, gloves and an autoclave.
Requires:
flow + training + processing + cleaning + disinfection + sterilization + monitoring + operational discipline.
Between one patient and another, we are not simply preparing the room. We are rebuilding safety conditions so that new assistance can begin.
CENTERS FOR DISEASE CONTROL AND PREVENTION (CDC). Sterilization and Disinfection. Dental Infection Prevention and Control, 2024.
CENTERS FOR DISEASE CONTROL AND PREVENTION (CDC). Best Practices for Environmental Infection Prevention and Control. Dental Infection Prevention and Control, 2024.
CENTERS FOR DISEASE CONTROL AND PREVENTION (CDC). Standard Precautions. Dental Infection Prevention and Control, 2024.
CENTERS FOR DISEASE CONTROL AND PREVENTION (CDC). Best Practices for Sterilization Monitoring in Dental Settings. Dental Infection Prevention and Control, 2024.
BRAZIL. National Health Surveillance Agency (ANVISA). RDC Resolution No. 15, of March 15, 2012. Provides for good practice requirements for the processing of health products. Brasília, DF, 2012.
BRAZIL. National Health Surveillance Agency (ANVISA). GVIMS/GGTES/ANVISA Technical Note nº 04/2020: guidelines for health services during dental care. Brasília, DF
Explore outros conteúdos, aprofunde seus conhecimentos e descubra novas possibilidades para sua carreira.