A single preparation, a dentate arch or an apparently simple restoration may seem like trivial cases for digitalization.
Until the scanner enters the mouth.
Suddenly, the capture starts to lose information, the model presents incomplete areas or the operator realizes that he needs to return to the same region several times.
This happens because the difficulty of a scan is not determined solely by the complexity of the treatment.
It is determined by the quality and continuity of the data that the system can acquire and relate during digitization. Factors such as scanning strategy, operator experience, area extension, environmental conditions and anatomical characteristics can interfere with the accuracy of the result (JODA et al., 2023).
The first point is to separate clinical complexity from acquisition complexity.
A preparation can be simple from a restorative point of view and yet have characteristics that make it difficult to capture.
Very subgingival margins, deep areas, surfaces with little geometric reference, posterior regions with limited access and partially covered structures can make data acquisition difficult.
This happens because the scanner needs to find enough features to recognize where it is and continue building the model.
That is:
The scanner is not just looking for teeth. You are looking for reliable geometric information.
One of the most underestimated factors during scanning is humidity.
Saliva, blood and other fluids can change the optical conditions of the surface and make it difficult to acquire certain details.
A recent study evaluating full-arch scans on implants found that increased humidity compromised the trueness of the scans, reinforcing the importance of saliva control during acquisition (MOTA, 2026).
This helps to explain a very common situation:
the preparation is excellent → access is adequate → but the margin remains difficult to capture.
Before blaming the equipment, it’s worth asking:
“How is the field?”
In a small area, the scanner needs to relate relatively little data.
As the area increases, the system needs to continue recording new acquisitions over an increasingly larger sequence of information.
Therefore, extensive scans may be more susceptible to the accumulation of small discrepancies.
The literature demonstrates that the accuracy of full-arch scans varies depending on the clinical scenario and that different scanners can present different performances depending on the situation evaluated (VITAI et al., 2023).
This is particularly relevant in cases of completely edentulous arches and extensive rehabilitation on implants, in which there are fewer stable anatomical references.
Here is one of the big challenges.
Imagine a completely edentulous arcade.
In a natural dentition, the scanner finds numerous surfaces with distinct geometric characteristics.
In an edentulous arch, especially in areas of mobile mucosa, there are much fewer stable references.
The literature shows that regions such as soft palate, bottom of the vestibule and sublingual region may present greater discrepancies precisely because they are mobile or poorly traceable structures (ACHMADI et al., 2025).
Therefore, a case that seems “simpler” because it has no teeth can be, from a digital acquisition point of view, much more challenging.
It is important to understand that there is not just: “passing the scanner through your mouth.” There is an acquisition strategy.
The sequence, direction, speed and way in which the operator connects different regions can influence the final reconstruction.
In an in vitro study that evaluated different scanning strategies for edentulous arches, both the scanner and the strategy used significantly influenced the trueness and the precision of the results (ELIAS et al., 2023).
In other words:
The same case can produce different results depending on how it was scanned.
That's why learning how to use a scanner shouldn't just mean learning where to press the button.
There is an interesting idea here:
the scanner may be the same, but two operators may produce different results.
A systematic review and meta-analysis published in 2026 found that inexperienced operators had, on average, lower trueness and longer scanning times than experienced operators. After training, there was an improvement in accuracy and a reduction in acquisition time (LIMONES et al., 2026).
This does not mean that an experienced operator can correct any limitation of the equipment.
It means that the operator's technique is part of the acquisition system.
Knowing the equipment, recognizing when a region has not been captured well and knowing when to return to an area are important clinical skills.
Here there is a particularly interesting situation.
The deeper or less accessible a given region is, the more difficult it may be for the scanner to obtain sufficient data.
A recent study evaluated different scanners in scanning endocrown preparations with different depths. The work included the Eagle IOS and demonstrated that the discrepancy varied depending on the region analyzed and the depth of preparation, although the values found remained within the clinical limits considered by the authors (MOTA et al., 2026).
This reinforces an important idea:
There is no “scanner accuracy” as an isolated number that explains all cases.
Performance needs to be interpreted considering the type of surface, geometry, depth and clinical situation.
In Eagle IOS, the software has a three-dimensional quality map that allows the professional to identify regions in which the acquired data may be insufficient and perform a new acquisition when necessary.
This changes an important part of the process.
The professional does not simply need to trust that: “if it appeared on the screen, everything is ok.”
The acquisition now has a verificationstep.
And this is a much more interesting principle than simply talking about scanning speed:
Scanning is acquiring. Verifying is validating.
The quality map works precisely as an acquisition control resource before the file moves to the next stage of the flow.
Before you just randomly scan again, take a break.
□ Is the field dry and clean?
□ Is the region really accessible?
□ Is the margin exposed?
□ Is the scanner receiving enough references?
□ Am I following a coherent strategy?
□ Am I trying to recover a small area or am I unnecessarily redoing an entire region?
□ Does the software indicate any region with insufficient data?
This analysis is usually much more efficient than simply “scanning again”.
When a seemingly simple case becomes difficult to scan, shouldn't the first question be:
“Why isn't the scanner working?”
The most useful question is:
“Which variable is making data acquisition difficult?”
It could be the humidity.
It could be anatomy.
It could be the depth.
It could be the absence of references.
It could be the strategy.
It could be the operator's technique.
And it could be a combination of several of these factors.
Digital scanning is a clinical process, not just a technological one.
And the better the dentist understands what the system needs to “see”, the more predictable the acquisition becomes.
ACHMADI, Athiyyah Aura et al. The accuracy of edentulous arch impression between intraoral scanner and laboratory scanner: a scoping review. BDJ Open, v. 11, no. 1, 13, 2025. DOI: 10.1038/s41405-025-00300-4.
LIMONES, Alvaro et al. Impact of operator experience on intraoral digital scanning: a systematic review, meta-analysis, and meta-regression. Journal of Prosthetic Dentistry, 2026. DOI: 10.1016/j.prosdent.2025.09.008.
VITAI, Viktória et al. Evaluation of the accuracy of intraoral scanners for complete-arch scanning: a systematic review and network meta-analysis. Journal of Dentistry, v. 137, 104636, 2023. DOI: 10.1016/j.jdent.2023.104636.
ELIAS, K. et al. Impact of intraoral scanner, scanning strategy, and scanned arch on the scan accuracy of edentulous arches: an in vitro study. Journal of Prosthetic Dentistry, 2023. DOI: 10.1016/j.prosdent.2023.01.027.
MOTA, Iago Fonseca Silva et al. Intraoral scanning of endocrown preparation on natural teeth in an in-vitro setting: a segmented trueness analysis. International Journal of Computerized Dentistry, 2026.
JODA, T. et al. A guide for maximizing the accuracy of intraoral digital scans. Part 1: operator factors. International Journal of Prosthodontics, 2023.
ALLIAGE / DABI ATLANTE. Eagle IOS — User Manual. Rev. 10, Jul. 2024.
Explore outros conteúdos, aprofunde seus conhecimentos e descubra novas possibilidades para sua carreira.